COMPUTE × POWER

SST & AI Infrastructure

The system uses an 800VDC main bus supplied from 10kV through multi-port SSTs, with A/B DC buses, in-row power racks, BBU/BESS and liquid-cooled AIDC modules.

SYSTEM LOGICMulti-port SSTs provide isolated conversion between 10kV AC and 800VDC, with dedicated ports for rack power, backup storage and cooling auxiliaries. The Physical AI platform coordinates power and cooling from equipment status and workload plans.
0110kV

Medium-voltage input

02800VDC

High-voltage DC bus

031-10MW

Modular capacity

04Physical AI

Power, compute and cooling control

PRODUCT ARCHITECTURE

Product List

01

SST Power Infrastructure

Medium-voltage isolation, multi-port power regulation, DC distribution and power-quality control for grids, storage systems and DC loads.

  • 10kV / 50kVA three-port SST prototype
  • 10kV / 1.25MVA multi-port SST
  • 10kV / 2MVA product platform
  • 20kV / 35kV technology platform
  • SiC power modules and controllers
  • Remote SST monitoring and maintenance
Industrial rendering of a multi-port medium-voltage SST energy router
Multi-port medium-voltage SST
02

AI Compute Infrastructure

Modular 800VDC power distribution, backup power and liquid cooling for high-density GPU clusters.

  • 1MW liquid-cooled compute pod
  • 2.5MW standard AIDC module
  • 10MW centralized AIDC
  • 800VDC A/B bus distribution
  • 800VDC in-row power rack and BBU
  • 2.4-3MW liquid-to-liquid CDU
Liquid-cooled modular AIDC pod
Liquid-cooled modular AIDC pod
03

Physical AI Coordination Platform

The platform reads equipment limits, operating state and forecasts, calculates power, compute and cooling schedules, and sends validated commands to edge controllers.

  • Heterogeneous compute scheduling
  • Joint power, compute and cooling optimization
  • Multi-campus compute aggregation
  • Digital twin and AIOps
  • Green-compute and carbon accounting
  • Edge execution agents
OpenEMS open-source cloud energy management live interface
Cloud energy management UI reference · OpenEMS

CORE TECHNOLOGY

Core Technology

01MACP-PET multi-port topology
02High-frequency SiC conversion
03DAB / CHB / MMC
04Model predictive control
05Power-compute-cooling world model
06Safety-constrained optimization

SOLUTIONS

Solutions

Project and system imagery is shown only for the solution it directly represents.

0110MW centralized AIDC→021MW liquid-cooled compute pod
Modular liquid-cooled AI data-center solution
Modular liquid-cooled AI data center
→
03SST-fed 800VDC power→04Multi-campus compute coordination→05AIDC storage and demand response→06Green compute operations→

START A CONVERSATION

Define the project scope
Review the system design

Provide the application, capacity, grid connection, load profile and project objectives. We will use them to define equipment, system interfaces and the scope of delivery.

Submit Project Requirements ↗

Power-electronic equipment and energy-system engineering for data centers, industrial campuses, vessels and charging sites.